# Beer-Lambert Law Calculator

URL: https://speedycalculator.com/calculators/chemistry/beer-lambert-law/
Last updated: 2026-11-08

> The Beer–Lambert law calculator finds absorbance and transmittance from molar absorptivity, concentration and path length, or solves for concentration, molar absorptivity or path length from a measured absorbance or %T, and gives the mass concentration if you add a molar mass.

## Inputs

- Solve for
- Measured value
- Absorbance (A)
- Transmittance (%T) (%)
- Molar absorptivity (ε) (L/(mol·cm), mM⁻¹·cm⁻¹, cm²/mol, m²/mol)
- Concentration (c) (µM, mM, M, nM)
- Path length (l) (cm, mm, m, µm)
- Molar mass (optional, for mass concentration) (g/mol, kg/mol, Da (u), kDa)

## Results

- Absorbance A
- Concentration c
- Molar absorptivity ε
- Path length l
- Absorbance used
- Transmittance T
- Share of light absorbed (1 − T)
- Mass concentration
- Reading quality

## Formula

```
A = ε·l·c · A = −log₁₀(T) = 2 − log₁₀(%T) · T = I ÷ I₀ = 10⁻ᴬ · c = A ÷ (ε·l) · ε = A ÷ (l·c) · l = A ÷ (ε·c)
```

## Explanation

When light passes through a solution, molecules that absorb at that wavelength remove a fixed fraction of it in every thin layer. The intensity therefore falls exponentially with distance, and the logarithm of the ratio of incoming to outgoing light, the absorbance A, grows in a straight line with both the path length l and the concentration c. The constant of proportionality is the molar absorptivity (molar attenuation coefficient) ε, a property of the substance at a given wavelength and solvent.

This linear relationship is what makes UV–visible spectrophotometry so useful. Measure the absorbance of an unknown in a 1 cm cuvette, divide by ε, and you have its concentration. No calibration is needed if ε is known reliably, as for NADH at 340 nm (6,220 M⁻¹·cm⁻¹) or for DNA and proteins at 260 and 280 nm. Transmittance T is the fraction of light that gets through; an absorbance of 1 lets 10% through, an absorbance of 2 only 1%.

The law works best for dilute solutions and monochromatic light. Above an absorbance of roughly 1–1.5 stray light, molecular interactions and instrument noise make readings non-linear, so concentrated samples should be diluted into the 0.1–1 range.

### How to use the Beer-Lambert Law Calculator

- **Solve for**
- **Measured value**
- **Absorbance (A)**
- **Transmittance (%T)**
- **Molar absorptivity (ε)**
- **Concentration (c)**
- **Path length (l)**
- **Molar mass (optional, for mass concentration)**

Results update as you type, every field has its own unit menu, and everything is calculated in your browser.

### How it works

Choose the unknown. For absorbance, enter ε, c and l. For the others, enter the measured absorbance (or percent transmittance) plus the two known quantities. The calculator converts all units to L·mol⁻¹·cm⁻¹, mol/L and cm before applying A = εlc.

### Worked example

NADH absorbs at 340 nm with ε = 6,220 L·mol⁻¹·cm⁻¹. A 50 µM solution in a 1 cm cuvette has A = 6,220 × 1 × 0.000050 = **0.311**, so T = 10⁻⁰·³¹¹ = 48.9% of the light gets through. With the molar mass 663.43 g/mol, 50 µM is 33.17 mg/L. Working backwards, a sample reading A = 0.45 contains c = 0.45 ÷ (6,220 × 1) = 7.235 × 10⁻⁵ mol/L = 72.35 µM.

### Absorbance and transmittance

AbsorbanceTransmittanceLight absorbed0100%0%0.179.4%20.6%0.30150%50%0.531.6%68.4%110%90%21%99%30.1%99.9%

### Inputs explained

FieldWhat to enterSolve forChoose one: Absorbance and transmittance, Concentration c, Molar absorptivity ε, Path length lMeasured valueChoose one: Absorbance A, Transmittance %TAbsorbance (A)A numberTransmittance (%T)In %Molar absorptivity (ε)Units: L/(mol·cm), mM⁻¹·cm⁻¹, cm²/mol, m²/molConcentration (c)Units: µM, mM, M, nMPath length (l)Units: cm, mm, m, µmMolar mass (optional, for mass concentration)Units: g/mol, kg/mol, Da (u), kDa

### What each result means

- **Absorbance A** = [absorbance]
- **Concentration c** = [conc]
- **Molar absorptivity ε** = [eps]
- **Path length l** = [path]
- **Absorbance used** = [absorbance]
- **Transmittance T** = (10^(-[absorbance]))×100
- **Share of light absorbed (1 − T)** = (1 - 10^(-[absorbance]))×100
- **Mass concentration** = [conc]×[Molar mass (optional, for mass concentration)]

## Worked example

Inputs: Solve for: Absorbance and transmittance; Molar absorptivity (ε): 6,220 L/(mol·cm); Concentration (c): 50 µM; Path length (l): 1 cm; Molar mass (optional, for mass concentration): 663.43 g/mol.

Results: **Absorbance A = 0.311**; Transmittance T = 48.865 %; Share of light absorbed (1 − T) = 51.135 %; Mass concentration = 0.0332 g/L; Reading quality = Within 0.1–1 – ideal linear range.

## Key terms

- **Absorbance (A)**: log₁₀ of incident over transmitted intensity, log₁₀(I₀/I).
- **Transmittance (T)**: Fraction of light that passes through the sample, I/I₀.
- **Molar absorptivity (ε)**: Absorbance of a 1 mol/L solution in a 1 cm cell at a given wavelength.
- **Path length (l)**: Distance the light travels through the sample, usually the cuvette width.

## FAQ

**What is the Beer–Lambert law?**
Absorbance is proportional to concentration and path length: A = ε·l·c. ε is the molar absorptivity of the substance at the chosen wavelength.

**What units does molar absorptivity have?**
L·mol⁻¹·cm⁻¹ (the same as M⁻¹·cm⁻¹). 1 mM⁻¹·cm⁻¹ = 1,000 L·mol⁻¹·cm⁻¹ and 1 m²/mol = 10 L·mol⁻¹·cm⁻¹.

**How do I convert transmittance to absorbance?**
A = −log₁₀(T) = 2 − log₁₀(%T). 50% T gives A = 0.301, 10% T gives A = 1 and 1% T gives A = 2.

**Why does absorbance have no unit?**
It is the logarithm of a ratio of two intensities, so the units cancel. It is sometimes written as "AU" (absorbance units).

**Why does the law fail at high concentration?**
Molecules start to interact, the refractive index changes and stray light becomes significant, so readings above about A = 1.5 bend below the straight line.

**What is the standard path length?**
1 cm for ordinary cuvettes. Microvolume spectrophotometers use 0.05–1 mm and scale the result to 1 cm.

**How do I measure DNA concentration with Beer–Lambert?**
For double-stranded DNA, an A260 of 1.0 in a 1 cm cell corresponds to about 50 µg/mL; single-stranded RNA about 40 µg/mL.


## Sources

- [IUPAC Compendium of Chemical Terminology (Gold Book)](https://goldbook.iupac.org/)
- [OpenStax: Chemistry 2e](https://openstax.org/details/books/chemistry-2e)
- [LibreTexts Chemistry](https://chem.libretexts.org/)