Crude Protein Calculator (Kjeldahl Nitrogen)

Quick answer

The crude protein calculator turns Kjeldahl titration data (titrant volumes for the sample and blank, titrant concentration, acid factor, dilution factor and sample mass) or a known nitrogen percentage into percent nitrogen and crude protein, using the general factor 6.25 or a food-specific Jones factor.

%
Nitrogen content
1.7229 %
Conversion factor used
6.25
Crude protein (as received)
10.768 %
Crude protein, dry-matter basis
12.236 %
Protein per 100 g of sample
10.77 g
Crude protein with the general factor 6.25
10.768 %
Protein in the weighed sample
0.1077
Check
Plausible result

Proteins are the only major food component that contains a lot of nitrogen, so the classic way to measure protein is to measure nitrogen and multiply by a conversion factor. In the Kjeldahl method (Johan Kjeldahl, 1883) the sample is digested in boiling concentrated sulfuric acid with a catalyst, which converts organic nitrogen into ammonium sulfate. Adding sodium hydroxide releases ammonia, which is distilled into boric acid (or into a known excess of standard acid) and titrated.

Average proteins contain about 16% nitrogen, so the default conversion factor is 100/16 = 6.25. The result is called crude protein because it counts all nitrogen (including non-protein nitrogen from free amino acids, nucleic acids, urea or, notoriously, melamine) as if it were protein.

D. Breese Jones showed in 1931–1941 that the nitrogen content of proteins varies with the food, and published specific factors: 6.38 for milk, 5.70 for wheat flour, 5.71 for soybeans, 5.46 for peanuts. Food labelling rules still use these “Jones factors”, while animal feed is almost always reported with 6.25. The Dumas combustion method gives total nitrogen directly: enter it in the second mode.

How to use the Crude Protein Calculator

  1. Nitrogen from
  2. Titration type
  3. Titrant volume for the sample
  4. Titrant volume for the blank
  5. Titrant concentration
  6. Acid factor F₁
  7. Dilution / aliquot factor F₂ (1 = whole digest titrated)
  8. Sample mass
  9. Nitrogen content
  10. Nitrogen-to-protein conversion factor
  11. Custom factor
  12. Moisture content of the sample (optional)

Results update as you type, every field has its own unit menu, and everything is calculated in your browser.

How it works

In titration mode the calculator subtracts the blank from the sample titre (or the sample from the blank for a back-titration), converts millilitres × mol/L into millimoles of nitrogen, multiplies by 14.007 mg/mmol and divides by the sample mass. Multiplying the nitrogen percentage by the conversion factor gives crude protein; entering the moisture content converts it to a dry-matter basis.

Worked example

A 1.000 g flour sample is digested and the ammonia is trapped in boric acid. Titration with 0.1000 M HCl takes 12.50 mL; the blank takes 0.20 mL. Nitrogen = (12.50 − 0.20) × 0.1000 × 1 × 1.4007 / 1.000 = 1.723%. With the general factor, crude protein = 1.723 × 6.25 = 10.77%; with the Jones factor for white wheat flour it is 1.723 × 5.70 = 9.82%. At 12% moisture the dry-matter crude protein (factor 6.25) is 10.77 / 0.88 = 12.24%.

Jones nitrogen-to-protein conversion factors

Food Factor
General / unknown food 6.25
Wheat, whole grain 5.83
Wheat flour, white 5.70
Wheat bran 6.31
Rice 5.95
Barley, oats, rye 5.83
Maize / corn 6.25
Soybeans 5.71
Peanuts / groundnuts 5.46
Almonds 5.18
Brazil nuts 5.46
Other tree nuts; sesame, sunflower seeds 5.30
Milk and dairy products 6.38
Eggs 6.25
Meat and fish 6.25
Gelatin 5.55

Factors from Jones (1941) as tabulated by FAO (2003). For feeds and for foods not listed, 6.25 is used.

Tips

  • Count halogens like hydrogens and ignore oxygen and sulfur in degree-of-unsaturation formulas.
  • Balance combustion with O₂ last: it is the easiest to adjust.
  • Use dry mass for combustion analysis and protein content.
  • Everything is calculated in your browser.

Common mistakes to avoid

  • Counting nitrogen like a hydrogen in degree of unsaturation (it subtracts one H).
  • Forgetting that one mole of CO₂ contains one mole of C.
  • Using the wrong Kjeldahl factor (6.25 is generic).

Inputs explained

Field What to enter
Nitrogen from Choose one: Kjeldahl titration data, Known nitrogen content (Dumas or lab report)
Titration type Choose one: Direct (ammonia trapped in boric acid, titrated with acid), Back-titration (excess standard acid titrated with NaOH)
Titrant volume for the sample Units: mL, L, µL
Titrant volume for the blank Units: mL, L, µL
Titrant concentration Units: mol/L (M), mmol/L (mM), µmol/L (µM), nmol/L (nM), mol/m³
Acid factor F₁ Choose one: 1 (HCl, or any titrant given as normality), 2 (H₂SO₄ given in mol/L)
Dilution / aliquot factor F₂ (1 = whole digest titrated) A number
Sample mass Units: g, mg, µg, kg, oz, lb
Nitrogen content In %
Nitrogen-to-protein conversion factor Choose one: General / unknown food (6.25), Wheat, whole grain (5.83), Wheat flour, white (5.70), Wheat bran (6.31) …
Custom factor A number
Moisture content of the sample (optional) In %

What each result means

  • Crude protein (as received) = [Nitrogen content]×[Conversion factor used]
  • Crude protein, dry-matter basis = [Nitrogen content]×[Conversion factor used]÷(1 – [Moisture content of the sample (optional)]÷100)
  • Protein per 100 g of sample = [Nitrogen content]×[Conversion factor used]
  • Crude protein with the general factor 6.25 = [Nitrogen content]×6.25
  • Protein in the weighed sample = [Nitrogen content]×[Conversion factor used]÷100×[Sample mass]

Formula

N (%) = (V_sample − V_blank) × c × F₁ × 1.4007 × F₂ ÷ m · CP (%) = N (%) × Jones factor · dry basis = CP ÷ (1 − moisture)

Worked example

Inputs: Nitrogen from: Kjeldahl titration data; Titration type: Direct – ammonia trapped in boric acid, titrated with acid; Titrant volume for the sample: 12.5 mL; Titrant volume for the blank: 0.2 mL; Titrant concentration: 0.1 mol/L (M); Acid factor F₁: 1 – HCl, or any titrant given as normality; Dilution / aliquot factor F₂ (1 = whole digest titrated): 1; Sample mass: 1 g; Nitrogen-to-protein conversion factor: General / unknown food (6.25); Moisture content of the sample (optional): 12 %.
Results: Nitrogen content = 1.7229 %; Conversion factor used = 6.25; Crude protein (as received) = 10.768 %; Crude protein, dry-matter basis = 12.236 %; Protein per 100 g of sample = 10.77 g; Crude protein with the general factor 6.25 = 10.768 %; Protein in the weighed sample = 0.1077 g; Check = Plausible result.

Key terms

Kjeldahl method
Wet digestion with sulfuric acid, distillation of ammonia and titration to measure organic plus ammonium nitrogen.
Dumas method
Combustion of the sample at about 1000 °C and measurement of the N₂ released.
Crude protein
Total nitrogen × conversion factor.
Jones factor
Food-specific nitrogen-to-protein conversion factor.
Dry-matter basis
Result expressed relative to the sample mass after removing water.

Frequently asked questions

Why is the protein factor 6.25?

Average proteins are about 16% nitrogen by mass, and 100/16 = 6.25. It is the default for feeds and for foods without a specific factor.

What are Jones factors?

Food-specific nitrogen-to-protein factors published by D. B. Jones (USDA, 1931/1941), e.g. 6.38 for milk, 5.70 for white wheat flour, 5.95 for rice, 5.71 for soybeans, 5.46 for peanuts and 5.18 for almonds. They are still used in food composition tables.

What is the difference between crude protein and true protein?

Crude protein counts all nitrogen as protein. True protein subtracts non-protein nitrogen (urea, free amino acids, nucleic acids, nitrate), which can be 5–25% of total nitrogen in forages and milk.

Where does the 1.4007 come from?

The atomic mass of nitrogen is 14.007 g/mol. (mL × mol/L) gives mmol of N; × 14.007 mg/mmol gives mg of N; ÷ (mass in g × 1000 mg/g) × 100 gives percent, which simplifies to × 1.4007 ÷ m.

When is the acid factor 2?

When the titrant is sulfuric acid and its concentration is given in mol/L: each H₂SO₄ neutralises two NH₃. If the concentration is given as normality, use 1.

What is a direct versus a back-titration?

In the modern boric acid method the trapped ammonia is titrated directly with standard acid, so the sample needs more titrant than the blank. In the older method ammonia is caught in a measured excess of standard acid and the leftover acid is titrated with NaOH, so the sample needs less titrant than the blank.

Why report protein on a dry-matter basis?

Moisture dilutes every nutrient. Dry-matter values let you compare hay at 12% moisture with silage at 65% moisture on an equal footing.

Sources

  1. FAO (2003), Food energy: methods of analysis and conversion factors (Food and Nutrition Paper 77)
  2. AOAC International: Official Methods of Analysis
  3. LibreTexts Chemistry

Cite this calculator

Speedy Calculator. (2026). Crude Protein Calculator (Kjeldahl Nitrogen). Speedy Calculator. https://speedycalculator.com/calculators/chemistry/crude-protein/