Hydraulic retention time (HRT) is the average time liquid stays in a reactor. In biological treatment (activated-sludge aeration tanks, anaerobic digesters, membrane bioreactors, chemostats) it decides how long microorganisms have to break down the dissolved pollutants before the water leaves. Too short an HRT and the organic load passes through untreated; much too long and the tank is larger and more expensive than it needs to be.
HRT is linked to the dilution rate D = Q/V, its reciprocal. In a continuously fed, completely mixed reactor without biomass recycle, the microbes are washed out whenever the dilution rate exceeds their maximum growth rate. Plants avoid this by keeping biomass much longer than water: the solids retention time (SRT, or sludge age) is held at several days to weeks while the HRT is only hours, by settling and returning sludge or by holding it behind membranes. The SRT/HRT ratio shows how strongly the system decouples the two.
Designers also look at the volumetric organic loading rate (kilograms of BOD entering per cubic metre of reactor per day), which combines HRT with influent strength. Use the second and third modes to size a new tank for a target HRT or to check how much flow an existing tank can take.
How to use the Hydraulic Retention Time Calculator
- Calculate
- Reactor (tank) volume
- Inflow rate
- Target HRT
- Influent BOD (or COD) concentration
- Include solids retention time (SRT)?
- Solids retention time (sludge age)
Results update as you type, every field has its own unit menu, and everything is calculated in your browser.
How it works
Choose whether to find the HRT, the reactor volume or the maximum flow. The calculator divides volume by flow (or multiplies flow by the target time), then derives the dilution rate, daily volume turnovers, organic loading from the influent BOD and, if you enter it, the ratio of solids to hydraulic retention time.
Worked example
An aeration tank of 2,500 m³ receives 8,000 m³/day of settled sewage with 200 mg/L BOD. The HRT is 2,500 ÷ 8,000 = 0.3125 day = 7.5 h, and the dilution rate is 3.2 d⁻¹ (the tank volume is exchanged 3.2 times a day). The organic loading is 8,000 m³/day × 0.200 kg/m³ ÷ 2,500 m³ = 0.64 kg BOD/(m³·day). With a sludge age of 10 days, SRT/HRT = 10 ÷ 0.3125 = 32. To bring the HRT down to a target of 6 h at the same flow you would need only 8,000 × 6 ÷ 24 = 2,000 m³, and the existing 2,500 m³ tank could take up to 2,500 × 24 ÷ 6 = 10,000 m³/day at 6 h.
Typical retention times
| Process | Typical HRT | Typical SRT |
|---|---|---|
| Conventional activated sludge | 4–8 h | 3–15 days |
| Extended aeration | 18–36 h | 20–30 days |
| Membrane bioreactor | 4–12 h | 10–30 days or more |
| Anaerobic digester (mesophilic) | 15–30 days | same as HRT |
Indicative values; the design basis for a specific plant takes precedence.
Inputs explained
| Field | What to enter |
|---|---|
| Calculate | Choose one: Hydraulic retention time, Reactor volume for a target HRT, Maximum inflow for a target HRT |
| Reactor (tank) volume | Units: m³, L, US gal, million US gal, ft³ |
| Inflow rate | Units: m³/day, m³/h, L/s, MGD (million US gal/day), US gal/min (gpm) |
| Target HRT | Units: h, min, days, s |
| Influent BOD (or COD) concentration | In mg/L |
| Include solids retention time (SRT)? | Choose one: No, Yes |
| Solids retention time (sludge age) | Units: days, h |
What each result means
- Hydraulic retention time = [hrt]
- Required reactor volume = [volume]
- Maximum inflow = [flow]
- Dilution rate D = Q ÷ V = 1÷[hrt]
- Reactor volumes exchanged per day = 86400÷[hrt]
- Volumetric organic loading rate = [flow]×[Influent BOD (or COD) concentration]÷[volume]×86.4
- SRT ÷ HRT = [Solids retention time (sludge age)]÷[hrt]
Formula
HRT = V ÷ Q · V = Q × HRT · Q_max = V ÷ HRT · dilution rate D = Q ÷ V = 1 ÷ HRT · organic loading = Q × BOD ÷ V · SRT ÷ HRT
Worked example
Inputs: Calculate: Hydraulic retention time; Reactor (tank) volume: 2,500 m³; Inflow rate: 8,000 m³/day; Influent BOD (or COD) concentration: 200 mg/L; Include solids retention time (SRT)?: Yes; Solids retention time (sludge age): 10 days.
Results: Hydraulic retention time = 7.5 h; Dilution rate D = Q ÷ V = 3.2 per day (d⁻¹); Reactor volumes exchanged per day = 3.2; Volumetric organic loading rate = 0.64 kg/(m³·day); SRT ÷ HRT = 32 ×.
Key terms
- Hydraulic retention time (HRT)
- Average time liquid remains in a reactor, V ÷ Q.
- Solids retention time (SRT)
- Average time biomass remains in the system; also called sludge age or mean cell residence time.
- Dilution rate
- Flow divided by reactor volume, the reciprocal of HRT.
- Washout
- Loss of the microbial population when it cannot grow as fast as it is flushed out.
- Organic loading rate
- Mass of BOD or COD fed per unit of reactor volume per day.
Frequently asked questions
What is the HRT formula?
HRT = V ÷ Q. A 3,000 m³ tank receiving 10,000 m³/day has HRT = 0.3 day = 7.2 hours.
What is a typical HRT for activated sludge?
Conventional activated sludge usually runs at about 4–8 hours; extended aeration at 18–36 hours. Anaerobic digesters run at roughly 15–30 days, where HRT and SRT are often the same.
What is the difference between HRT and SRT?
HRT is how long the water stays; SRT is how long the biomass stays. With sludge recycle or membranes the SRT (days to weeks) is far longer than the HRT (hours).
What happens if the HRT is too short?
Without biomass retention, microbes wash out once the dilution rate Q/V exceeds their maximum growth rate; even with retention, a short HRT can leave biodegradable organics unoxidised.
What is the dilution rate?
D = Q/V = 1/HRT. In a chemostat at steady state the specific growth rate of the culture equals D.
How do I size a tank for a given HRT?
Multiply the design flow by the target HRT: 8,000 m³/day × 6 h ÷ 24 h/day = 2,000 m³.
What is the volumetric organic loading rate?
The mass of BOD (or COD) entering per cubic metre of reactor per day, Q × BOD ÷ V. Conventional activated sludge is often loaded at roughly 0.3–0.7 kg BOD/(m³·day).