Langmuir Isotherm Calculator

Quick answer

The Langmuir isotherm calculator finds the fractional surface coverage θ of an adsorbent from the adsorption equilibrium constant and the gas partial pressure (or the solute concentration for adsorption from solution), with optional dissociative adsorption and the amount adsorbed per gram.

Surface coverage θ
0.6667
Surface coverage (percent)
66.67 %
Free (vacant) sites
33.33 %
Dimensionless product K·P (or K·c)
2
Amount adsorbed q
1
Pressure for 50% coverage
1.25
Pressure for 90% coverage
11.25
Region of the isotherm
Intermediate coverage – curved part of the isotherm

Adsorption is the build-up of molecules from a gas or a solution on the surface of a solid: activated carbon in a water filter, a catalyst in a reactor, a zeolite drying compressed air. In 1918 Irving Langmuir described it with a simple model: the surface has a fixed number of identical sites, each site holds at most one molecule, the molecules do not interact with each other, and adsorption and desorption are in dynamic equilibrium.

Balancing the rate of adsorption (proportional to pressure and to the free sites) against the rate of desorption (proportional to the occupied sites) gives the Langmuir isotherm. At low pressure the coverage rises almost linearly with pressure (θ ≈ K·P, Henry’s-law region); at high pressure it levels off towards a complete monolayer, θ → 1.

The equilibrium constant K measures how strongly the adsorbate binds: the larger K, the lower the pressure needed to fill the surface. Exactly half of the sites are occupied when K·P = 1, so 1/K is the half-coverage pressure. When a molecule such as H₂ splits into two atoms that each take a site, the dissociative form with √(K·P) applies.

How to use the Langmuir Isotherm Calculator

  1. Adsorbate
  2. Type of adsorption
  3. Equilibrium constant K
  4. Partial pressure of the gas P
  5. Equilibrium constant K
  6. Equilibrium concentration c
  7. Monolayer capacity q_max (optional)

Results update as you type, every field has its own unit menu, and everything is calculated in your browser.

How it works

Choose whether the adsorbate is a gas (enter K in reciprocal pressure units and the partial pressure) or a dissolved solute (K in L/mol and the concentration). The product K·P (or K·c) gives θ; multiplying θ by the monolayer capacity q_max gives the amount adsorbed.

Worked example

A gas adsorbs on a catalyst with K = 0.8 atm⁻¹ at a partial pressure of 2.5 atm. K·P = 2.0, so θ = 2.0 / (1 + 2.0) = 0.667: two thirds of the sites are occupied and one third are free. If the monolayer capacity is 1.5 mmol/g, the catalyst holds 1.5 × 0.667 = 1.0 mmol/g. Half coverage needs P = 1/K = 1.25 atm and 90% coverage needs 9/K = 11.25 atm.

If the same gas adsorbed dissociatively, √(K·P) = √2 = 1.414 and θ = 1.414 / 2.414 = 0.586. That is lower, because each molecule needs two neighbouring free sites.

How the coverage grows with pressure

K·P θ (molecular) θ (dissociative)
0.01 0.010 0.091
0.10 0.091 0.240
0.50 0.333 0.414
1.00 0.500 0.500
2.00 0.667 0.586
5.00 0.833 0.691
9.00 0.900 0.750
20.00 0.952 0.817
100.00 0.990 0.909

Each tenfold increase in pressure adds less and less coverage once K·P passes about 1: the surface is filling up.

Inputs explained

Field What to enter
Adsorbate Choose one: Gas (partial pressure), Solute in a liquid (concentration)
Type of adsorption Choose one: Molecular (one molecule per site), Dissociative (molecule splits over two sites, e.g. H₂)
Equilibrium constant K Units: 1/atm, 1/bar, 1/kPa, 1/Pa, 1/mmHg (1/Torr)
Partial pressure of the gas P Units: atm, kPa, Pa, bar, mmHg (Torr), psi
Equilibrium constant K Units: L/mol (1/M), L/mmol (1/mM), m³/mol
Equilibrium concentration c Units: mol/L (M), mmol/L (mM), µmol/L (µM), nmol/L (nM), mol/m³
Monolayer capacity q_max (optional) Units: mmol/g, mol/kg, µmol/g, mol/g

What each result means

  • Surface coverage (percent) = ([Surface coverage θ])×100
  • Free (vacant) sites = (1 – [Surface coverage θ])×100
  • Dimensionless product K·P (or K·c) = [K·P]
  • Amount adsorbed q = [Monolayer capacity q_max (optional)]×[Surface coverage θ]
  • Pressure for 50% coverage = 1÷[Equilibrium constant K]
  • Concentration for 50% coverage = 1÷[Equilibrium constant K]

Formula

θ = K·P ÷ (1 + K·P) (gas) · θ = K·c ÷ (1 + K·c) (solution) · dissociative: θ = √(K·P) ÷ (1 + √(K·P)) · q = q_max·θ

Worked example

Inputs: Adsorbate: Gas – partial pressure; Type of adsorption: Molecular (one molecule per site); Equilibrium constant K: 0.8 1/atm; Partial pressure of the gas P: 2.5 atm; Monolayer capacity q_max (optional): 1.5 mmol/g.
Results: Surface coverage θ = 0.6667; Surface coverage (percent) = 66.67 %; Free (vacant) sites = 33.33 %; Dimensionless product K·P (or K·c) = 2; Amount adsorbed q = 1 mmol/g; Pressure for 50% coverage = 1.25 atm; Pressure for 90% coverage = 11.25 atm; Region of the isotherm = Intermediate coverage – curved part of the isotherm.

Key terms

Adsorbent
The solid whose surface takes up the molecules (activated carbon, silica, zeolite, metal catalyst).
Adsorbate
The molecule that sticks to the surface.
Surface coverage θ
Fraction of adsorption sites occupied, from 0 (bare) to 1 (full monolayer).
Monolayer capacity q_max
Amount of adsorbate per gram of adsorbent when every site is occupied.
Chemisorption / physisorption
Adsorption through chemical bonds (strong, one layer) versus van der Waals forces (weak, can form multilayers).

Frequently asked questions

What does the Langmuir isotherm describe?

How the fraction of occupied adsorption sites θ depends on pressure (or concentration) at constant temperature, assuming a uniform surface and a single layer of adsorbed molecules.

What are the units of K?

Reciprocal pressure for gases (1/atm, 1/bar, 1/Pa) and reciprocal concentration for solutions (L/mol). K·P must be dimensionless, so K and P must use matching units. The unit menus take care of that.

What coverage does K·P = 1 give?

Exactly 50%. With K = 0.8 atm⁻¹ that happens at 1/0.8 = 1.25 atm; 90% coverage needs K·P = 9, i.e. 11.25 atm.

How do I find K and q_max from experimental data?

Plot P/q against P (linearised Langmuir plot). The slope is 1/q_max and the intercept is 1/(K·q_max). Non-linear least-squares fitting is more reliable when the data are noisy.

When does the Langmuir model fail?

On heterogeneous surfaces, when adsorbed molecules interact, and when multilayers form (physisorption near the condensation pressure). Freundlich, Temkin or BET isotherms then fit better.

What is dissociative adsorption?

A diatomic molecule such as H₂ or O₂ splits into two atoms on a metal surface, each using one site. Coverage then depends on √P: θ = √(KP)/(1 + √(KP)).

How does temperature affect K?

Adsorption is exothermic, so K falls as temperature rises (van 't Hoff behaviour): hotter surfaces hold less adsorbate at the same pressure.

Sources

  1. IUPAC Compendium of Chemical Terminology (Gold Book)
  2. Langmuir (1918), The adsorption of gases on plane surfaces of glass, mica and platinum, J. Am. Chem. Soc. 40, 1361
  3. LibreTexts Chemistry

Cite this calculator

Speedy Calculator. (2026). Langmuir Isotherm Calculator. Speedy Calculator. https://speedycalculator.com/calculators/chemistry/langmuir-isotherm/