Boiler Size Calculator

Quick answer

The boiler size calculator estimates the boiler output in kW for combi, system and heat-only boilers from the number of bedrooms and bathrooms and the age or insulation of the property.

Heating load
16
Hot-water demand (combi)
30
Minimum boiler output
30

Boiler size depends on two jobs: heating the house and producing hot water. A combi boiler heats water on demand, so its size is set by how many showers or taps may run at once, usually 24–35 kW. System and heat-only boilers store hot water in a cylinder, so they are sized for the heating load plus a little for reheating the cylinder. Older, poorly insulated homes need more heat per room.

How to use the Boiler Size Calculator

  1. Boiler type
  2. Bedrooms
  3. Bathrooms
  4. Age / insulation of property

Results update as you type, and every field accepts the units shown in its menu.

How it works

Choose the boiler type, enter the number of bedrooms and bathrooms and pick the age or insulation level of the property. The calculator estimates the heating load and the hot-water load and returns the minimum output to look for. A heat-loss survey by an installer gives the definitive figure.

Typical sizes

Home Combi System / heat only
1–2 bed, 1 bath 24–27 kW 12–15 kW
3–4 bed, 1–2 bath 28–34 kW 18–24 kW
4+ bed, 2+ bath 35–42 kW 30–40 kW

Inputs explained

Field What to enter
Boiler type Choose one: Combi, System, Heat only (regular)
Bedrooms A number
Bathrooms A number
Age / insulation of property Choose one: Built after 2000 or well insulated, 1976–2000, average insulation, 1930–1975, some upgrades, Before 1930, solid walls

What each result means

  • Heating load = (4 + 4×[Bedrooms])×[Age ÷ insulation of property]×1000
  • Hot-water demand (combi) = (24 + 6×([Bathrooms] – 1))×1000

Formula

Heating load ≈ (4 + 4 × bedrooms) kW × insulation factor Combi: hot-water demand ≈ 24 kW + 6 kW per extra bathroom; size = max(heating, hot water) System: heating + 3 kW for cylinder reheat; heat-only: heating + 3 kW

Worked example

Inputs: Boiler type: Combi; Bedrooms: 3; Bathrooms: 2; Age / insulation of property: 1976–2000, average insulation.
Results: Heating load = 16 kW; Hot-water demand (combi) = 30 kW; Minimum boiler output = 30 kW.

Frequently asked questions

What size combi boiler do I need for a 3-bed house with 2 bathrooms?

Typically 28–35 kW, mainly to supply two showers at once.

Is a bigger boiler better?

No. Modern condensing boilers are most efficient when they are not oversized; they modulate down but short-cycle if far too big.

What is the difference between combi, system and regular boilers?

A combi heats water on demand; a system boiler heats a sealed cylinder; a regular (heat-only) boiler works with a cylinder and a loft tank.

Sources

  1. Energy Saving Trust: Choosing a boiler

Cite this calculator

Speedy Calculator. (2026). Boiler Size Calculator. Speedy Calculator. https://speedycalculator.com/calculators/construction/boiler-size/