Glass is strong in compression but breaks in tension, and an aquarium panel is a plate bent outwards by water pressure that grows linearly with depth. The standard design method used by aquarium builders treats each front and side panel as a rectangular plate supported on three edges (bottom and both sides, the top edge free unless braced) under a triangular hydrostatic load, and the bottom as a plate supported on all four edges under uniform pressure. Tabulated plate coefficients β (for stress) and α (for deflection) from Roark’s Formulas for Stress and Strain depend on the panel’s aspect ratio.
The required thickness follows from setting the bending stress equal to the glass’s breaking strength divided by a safety factor. Annealed float glass is usually given a design strength of 19.2 MPa together with a safety factor of 3.8; long, tall panels need the most glass because the stress grows with the cube of the water height. The calculator interpolates β and α for your panel ratios, rounds each panel up to the next standard sheet thickness and estimates how much the panel bows outwards.
It also gives the tank’s volume, glass area and the weights of glass and water, so you can size the stand. For tanks over about 60 cm (24 in) tall, rimless display tanks or tempered or laminated glass, have the design checked by a professional.
How to use the Aquarium Glass Thickness Calculator
- Length
- Width (front to back)
- Height (water depth)
- Safety factor: 3.8 is the usual value for annealed float glass in aquariums.
- Glass design (breaking) strength: 19.2 MPa for annealed float glass; tempered glass is about 4–5× stronger.
- Water density: 998 kg/m³ fresh water, about 1,025 kg/m³ sea water.
- Glass density
Results update as you type, every field has its own unit menu, and everything is calculated in your browser.
How it works
Enter the inside length, width (front to back) and water height, the safety factor and the glass strength. The tool computes the front and side panels from their length/height ratios, the bottom from the length/width ratio, then rounds up to standard glass sizes.
Worked example
Tank 120 × 50 × 50 cm, fresh water (998 kg/m³), SF 3.8, σ = 19.2 MPa. The front panel ratio is 120/50 = 2.4, so β = 0.344 and t = √(0.344 × 998 × 9.807 × 0.5³ × 3.8 ÷ 19.2 × 10⁶) = 9.13 mm → use 10 mm. The side ratio is 1.0 (β = 0.16) → 6.22 mm → 8 mm. The bottom ratio 120/50 = 2.4 gives β = 0.651 and t = √(0.651 × 998 × 9.807 × 0.5 × 0.5² × 3.8 ÷ 19.2 × 10⁶) = 12.56 mm → 15 mm. The tank holds 300 L (299.4 kg of water) and the glass at the minimum thicknesses weighs about 54.0 kg.
Plate coefficients used
| Length ÷ height (sides) | β | α |
|---|---|---|
| 0.5 | 0.085 | 0.003 |
| 0.667 | 0.1156 | 0.0085 |
| 1 | 0.16 | 0.022 |
| 1.5 | 0.26 | 0.042 |
| 2 | 0.32 | 0.056 |
| 2.5 | 0.35 | 0.063 |
| 3 | 0.37 | 0.067 |
Inputs explained
| Field | What to enter |
|---|---|
| Length | Units: cm, in, mm, ft, m |
| Width (front to back) | Units: cm, in, mm, ft, m |
| Height (water depth) | Units: cm, in, mm, ft, m |
| Safety factor | A number. 3.8 is the usual value for annealed float glass in aquariums. |
| Glass design (breaking) strength | Units: MPa, psi, N/mm². 19.2 MPa for annealed float glass; tempered glass is about 4–5× stronger. |
| Water density | Units: kg/m³, lb/ft³, g/cm³. 998 kg/m³ fresh water, about 1,025 kg/m³ sea water. |
| Glass density | Units: kg/m³, lb/ft³, g/cm³ |
What each result means
- Front and back glass, minimum = sqrt([β front]×[Water density]×9.80665×[Height (water depth)]^3×[Safety factor]÷[Glass design (breaking) strength])
- Side glass, minimum = sqrt([β side]×[Water density]×9.80665×[Height (water depth)]^3×[Safety factor]÷[Glass design (breaking) strength])
- Bottom glass, minimum = sqrt([β bottom]×[Water density]×9.80665×[Height (water depth)]×min([Length], [Width (front to back)])^2×[Safety factor]÷[Glass design (breaking) strength])
- Front panel deflection = [α front]×[Water density]×9.80665×[Height (water depth)]^5÷(69e9×[Front and back glass, minimum]^3)
- Bottom panel deflection (unsupported) = [α bottom]×[Water density]×9.80665×[Height (water depth)]×min([Length], [Width (front to back)])^4÷(69e9×[Bottom glass, minimum]^3)
- Water pressure at the bottom = [Water density]×9.80665×[Height (water depth)]
- Aquarium volume = [Length]×[Width (front to back)]×[Height (water depth)]
- Glass area (sides + bottom) = 2×([Length] + [Width (front to back)])×[Height (water depth)] + [Length]×[Width (front to back)]
- Glass weight (minimum thicknesses) = (2×[Length]×[Height (water depth)]×[Front and back glass, minimum] + 2×[Width (front to back)]×[Height (water depth)]×[Side glass, minimum] + [Length]×[Width (front to back)]×[Bottom glass, minimum])×[Glass density]
- Water weight = [Length]×[Width (front to back)]×[Height (water depth)]×[Water density]
- Total weight = [Glass weight (minimum thicknesses)] + [Water weight]
Formula
Side panel: t = √(β · ρ · g · H³ · SF ÷ σ), β from the panel's length ÷ height ratio (3 edges supported, top free)
Bottom: t = √(β_b · ρ · g · H · w² · SF ÷ σ), w = shorter side, β_b from long ÷ short side
Deflection δ = α · ρ · g · H · b⁴ ÷ (E · t³), E = 69 GPa
Worked example
Inputs: Length: 120 cm; Width (front to back): 50 cm; Height (water depth): 50 cm; Safety factor: 3.8; Glass design (breaking) strength: 19.2 MPa; Water density: 998 kg/m³; Glass density: 2,500 kg/m³.
Results: Front and back glass – minimum = 9.13 mm; Side glass – minimum = 6.22 mm; Bottom glass – minimum = 12.56 mm; Recommended front/side sheet = 10 mm; Recommended bottom sheet = 15 mm; Front panel deflection = 0.36 mm; Bottom panel deflection (unsupported) = 0.27 mm; Water pressure at the bottom = 4.89 kPa; Aquarium volume = 300 L; Glass area (sides + bottom) = 2.3 m²; Glass weight (minimum thicknesses) = 54 kg; Water weight = 299.4 kg; Total weight = 353.4 kg.
Key terms
- Safety factor
- Ratio between the glass's breaking strength and the stress allowed in the design.
- Modulus of rupture
- The bending (tensile) stress at which glass breaks; 19.2 MPa is the design value used for annealed float glass.
- Plate coefficient β
- Dimensionless factor from plate theory that links pressure, span and thickness to bending stress.
- Deflection
- How far the centre of a panel bows outwards under load.
- Hydrostatic pressure
- Pressure of a liquid at rest, ρ·g·h, rising linearly with depth.
Frequently asked questions
How thick should aquarium glass be?
It depends mostly on water height. With a safety factor of 3.8, a 120 × 50 × 50 cm tank needs about 9.1 mm front glass (use 10 mm), 6.2 mm sides (use 8 mm) and 12.6 mm bottom glass (use 15 mm or 12 mm on a fully supported mat).
Why does height matter more than length?
Thickness grows with H^1.5: water pressure rises with depth and the bending span is the height, so doubling height needs about 2.8 times the glass.
What safety factor should I use?
3.8 is standard for annealed float glass in home aquariums; some builders use 3.0–3.5 for tempered glass and up to 5 for public displays.
Why is the bottom glass thicker?
The bottom carries the full pressure ρ·g·H everywhere, while side panels see pressure rising from zero at the surface; if the bottom sits on a flat, soft mat, the load is mostly carried by the stand.
Does bracing reduce the thickness?
Yes. A top rim or euro-bracing supports the top edge, reducing stress in long panels. The calculator assumes an unbraced top, which is conservative.
How much does glass weigh?
About 2.5 kg per square metre per millimetre of thickness (2,500 kg/m³). The example tank's glass weighs about 54 kg at the minimum thicknesses.
Is low-iron glass stronger?
No, it is optically clearer but with the same strength as ordinary float glass.