Every cable that carries fast signals or radio frequencies behaves as a transmission line with a characteristic impedance, Z₀. It is the ratio of voltage to current of a wave travelling along the line, set purely by the geometry of the conductors and the insulation between them, not by the length. When the source, cable and load share the same impedance, signals pass without reflections.
For a coaxial cable, Z₀ depends on the ratio of the shield’s inner diameter D to the centre conductor’s diameter d and on the dielectric constant εr of the insulation. That is why RG-58 and RG-213 are both 50 Ω despite different sizes, and why 75 Ω TV coax has a thinner centre conductor. For a twisted pair or parallel-wire line, Z₀ depends on the spacing between the wires relative to their diameter; Ethernet cable is built for about 100 Ω.
The same geometry gives the capacitance and inductance per metre, the speed at which signals travel (velocity factor 1 ÷ √εr) and, for coax, the frequency above which higher-order modes appear and the cable stops behaving as a simple line.
How to use the Cable Impedance Calculator
- Cable type
- Inner conductor diameter (d)
- Inner diameter of the shield (D)
- Centre-to-centre wire spacing (s)
- Insulation (dielectric)
- Relative permittivity (εr)
- Cable length
Results update as you type, every field has its own unit menu, and everything is calculated in your browser.
How it works
Pick the cable type, enter the conductor diameter and the shield diameter (coax) or wire spacing (twisted pair), and choose the insulation. The calculator evaluates the logarithmic impedance formula and derives capacitance, inductance and delay from the same geometry.
Worked example
RG-58 has a 0.81 mm centre conductor inside 2.95 mm of solid polyethylene (εr = 2.25). Z₀ = 59.96 ÷ 1.5 × ln(2.95 ÷ 0.81) = 39.97 × 1.2925 = 51.7 Ω. Its capacitance is about 96.8 pF/m, its inductance 258.5 nH/m, its delay 5.00 ns/m (velocity factor 0.667) and its TE11 cutoff is about 33.8 GHz.
Common cables
| Cable | Impedance | Dielectric | Velocity factor |
|---|---|---|---|
| RG-58 | 50 Ω | Solid PE | 0.66 |
| RG-213 | 50 Ω | Solid PE | 0.66 |
| RG-6 | 75 Ω | Foam PE | 0.82–0.85 |
| LMR-400 | 50 Ω | Foam PE | 0.85 |
| Cat 6 pair | 100 Ω | PE / FEP | 0.64–0.70 |
Inputs explained
| Field | What to enter |
|---|---|
| Cable type | Choose one: Coaxial cable, Twisted pair or parallel wires |
| Inner conductor diameter (d) | Units: mm, mil, µm, in, cm |
| Inner diameter of the shield (D) | Units: mm, mil, µm, in, cm |
| Centre-to-centre wire spacing (s) | Units: mm, mil, µm, in, cm |
| Insulation (dielectric) | Choose one: Air: εr 1.0, Foam polyethylene: εr ≈ 1.5, Solid polyethylene: εr 2.25, PTFE (Teflon): εr 2.1 … |
| Relative permittivity (εr) | A number |
| Cable length | Units: m, km, mi, ft, cm |
What each result means
- Delay per length = sqrt([εr used])÷299792458
- Velocity factor = 1÷sqrt([εr used])
- Total capacitance of the cable = [Capacitance per length]×[Cable length]
- Total delay of the cable = [Delay per length]×[Cable length]
Formula
Coax: Z₀ = (59.96 ÷ √εr) × ln(D ÷ d) · Twisted pair: Z₀ = (119.9 ÷ √εr) × ln(2s ÷ d) · C = 2πε₀εr ÷ ln(D/d) · L = (μ₀ ÷ 2π) ln(D/d) · delay = √εr ÷ c · TE11 cutoff ≈ 2c ÷ [π(D + d)√εr]
Worked example
Inputs: Cable type: Coaxial cable; Inner conductor diameter (d): 0.81 mm; Inner diameter of the shield (D): 2.95 mm; Insulation (dielectric): Solid polyethylene – εr 2.25; Cable length: 1 m.
Results: εr used = 2.25; Characteristic impedance = 51.67 Ω; Capacitance per length = 96.8438 pF/m; Inductance per length = 258.5052 nH/m; Delay per length = 5.0035 ns/m; Velocity factor = 0.667; Cutoff frequency (first higher-order mode, TE11) = 33.8393 GHz; Total capacitance of the cable = 96.8438 pF; Total delay of the cable = 5.0035 ns.
Key terms
- Characteristic impedance (Z₀)
- Ratio of voltage to current for a wave travelling along a line.
- Relative permittivity (εr)
- How much the insulation slows the wave and increases capacitance compared with vacuum.
- Velocity factor
- Signal speed in the cable as a fraction of the speed of light, 1 ÷ √εr.
- TE11 mode
- The first waveguide mode a coaxial cable can support above its cutoff frequency.
Frequently asked questions
Why are coax cables 50 Ω or 75 Ω?
50 Ω is a compromise between maximum power handling (about 30 Ω) and lowest loss (about 77 Ω); 75 Ω is close to minimum loss and is used for video and TV.
Does cable length change impedance?
No, characteristic impedance depends only on the cross-section; length changes loss, delay and total capacitance.
What is the impedance of Ethernet cable?
Category 5e, 6 and 6A twisted pairs are specified at 100 Ω ± 15 Ω.
Can I measure characteristic impedance with an ohmmeter?
No, it is an AC property. Use a TDR, a network analyser or measure capacitance and inductance per length and take √(L ÷ C).
What is the velocity factor of RG-58?
About 0.66 for solid polyethylene insulation; foam versions reach 0.78–0.85.
What is the cutoff frequency?
Above it, the coax can carry waveguide modes as well as the normal TEM mode, which distorts signals, so keep the operating frequency well below it.