Friction Loss Calculator (Hazen–Williams)

Quick answer

The friction loss calculator finds the head loss and pressure loss of water flowing through a pipe with the Hazen–Williams equation, from the flow rate, pipe length, inner diameter and pipe material (C factor).

Head loss
11.83239
Pressure loss
115.82721
Flow velocity
2.5465
Head loss per 100 m
11.8324 m

The Hazen–Williams formula is the everyday tool of water engineers for sizing water mains, sprinkler and irrigation systems. Smoother pipes have a higher C factor and lose less pressure.

How to use the Friction Loss Calculator

  1. Flow rate Q
  2. Pipe length L
  3. Inner diameter d
  4. Pipe material (C factor)
  5. Hazen–Williams C

Results update as you type, every field has its own unit menu, and everything is calculated in your browser.

How it works

Choose the pipe material, enter the flow rate, length and inner diameter.

Inputs explained

Field What to enter
Flow rate Q Units: L/s, m³/s, m³/h, L/min, US gpm, ft³/s
Pipe length L Units: m, cm, mm, km, in, ft …
Inner diameter d Units: mm, cm, m, in, µm
Pipe material (C factor) Choose one: PVC / plastic, HDPE, Copper, Ductile iron (cement lined) …
Hazen–Williams C A number

What each result means

  • Head loss = 10.67×[Pipe length L]×[Flow rate Q]^1.852÷([C]^1.852×[Inner diameter d]^4.8704)
  • Pressure loss = 998.2×9.80665×[Head loss]
  • Flow velocity = [Flow rate Q]÷(pi×[Inner diameter d]^2÷4)
  • Head loss per 100 m = [Head loss]÷[Pipe length L]×100

Example values

How the main result changes when Flow rate Q changes and everything else stays at the example values above:

Flow rate Q (L/s) Head loss (m)
2.5 3.2777
3.75 6.9452
5 11.8324
6.25 17.8875
7.5 25.0723
10 42.7149

Formula

h_f = 10.67·L·Q^{1.852} / (C^{1.852}·d^{4.8704}) (SI: m, m³/s), ΔP = ρ·g·h_f

Worked example

Inputs: Flow rate Q: 5 L/s; Pipe length L: 100 m; Inner diameter d: 50 mm; Pipe material (C factor): PVC / plastic.
Results: Head loss = 11.83239 m; Pressure loss = 115.82721 kPa; Flow velocity = 2.5465 m/s; Head loss per 100 m = 11.8324 m.

Key terms

Hazen–Williams C
Empirical smoothness coefficient.

Frequently asked questions

When is Hazen–Williams valid?

For water at normal temperatures in turbulent flow.

What is the C factor?

A roughness coefficient, where higher is smoother.

Does pipe age matter?

Yes. Corrosion and deposits reduce C over time.

Should I use Darcy–Weisbach instead?

For fluids other than water, or for higher accuracy.

Sources

  1. Fluid Mechanics (F. M. White): reference text
  2. The Engineering ToolBox

Cite this calculator

Speedy Calculator. (2026). Friction Loss Calculator (Hazen–Williams). Speedy Calculator. https://speedycalculator.com/calculators/physics/friction-loss/