The Hazen–Williams formula is the everyday tool of water engineers for sizing water mains, sprinkler and irrigation systems. Smoother pipes have a higher C factor and lose less pressure.
How to use the Friction Loss Calculator
- Flow rate Q
- Pipe length L
- Inner diameter d
- Pipe material (C factor)
- Hazen–Williams C
Results update as you type, every field has its own unit menu, and everything is calculated in your browser.
How it works
Choose the pipe material, enter the flow rate, length and inner diameter.
Inputs explained
| Field | What to enter |
|---|---|
| Flow rate Q | Units: L/s, m³/s, m³/h, L/min, US gpm, ft³/s |
| Pipe length L | Units: m, cm, mm, km, in, ft … |
| Inner diameter d | Units: mm, cm, m, in, µm |
| Pipe material (C factor) | Choose one: PVC / plastic, HDPE, Copper, Ductile iron (cement lined) … |
| Hazen–Williams C | A number |
What each result means
- Head loss = 10.67×[Pipe length L]×[Flow rate Q]^1.852÷([C]^1.852×[Inner diameter d]^4.8704)
- Pressure loss = 998.2×9.80665×[Head loss]
- Flow velocity = [Flow rate Q]÷(pi×[Inner diameter d]^2÷4)
- Head loss per 100 m = [Head loss]÷[Pipe length L]×100
Example values
How the main result changes when Flow rate Q changes and everything else stays at the example values above:
| Flow rate Q (L/s) | Head loss (m) |
|---|---|
| 2.5 | 3.2777 |
| 3.75 | 6.9452 |
| 5 | 11.8324 |
| 6.25 | 17.8875 |
| 7.5 | 25.0723 |
| 10 | 42.7149 |
Formula
h_f = 10.67·L·Q^{1.852} / (C^{1.852}·d^{4.8704}) (SI: m, m³/s), ΔP = ρ·g·h_f
Worked example
Inputs: Flow rate Q: 5 L/s; Pipe length L: 100 m; Inner diameter d: 50 mm; Pipe material (C factor): PVC / plastic.
Results: Head loss = 11.83239 m; Pressure loss = 115.82721 kPa; Flow velocity = 2.5465 m/s; Head loss per 100 m = 11.8324 m.
Key terms
- Hazen–Williams C
- Empirical smoothness coefficient.
Frequently asked questions
When is Hazen–Williams valid?
For water at normal temperatures in turbulent flow.
What is the C factor?
A roughness coefficient, where higher is smoother.
Does pipe age matter?
Yes. Corrosion and deposits reduce C over time.
Should I use Darcy–Weisbach instead?
For fluids other than water, or for higher accuracy.