# Ideal Transformer Calculator

URL: https://speedycalculator.com/calculators/physics/ideal-transformer/
Last updated: 2026-11-08

> The ideal transformer calculator finds the secondary voltage and current of a transformer from the primary voltage, current and the number of turns, plus the turns ratio and impedance ratio.

## Inputs

- Primary turns N_p
- Secondary turns N_s
- Primary voltage V_p (V, kV, mV)
- Primary current I_p (A, mA, µA, kA)

## Results

- Turns ratio N_p/N_s
- Secondary voltage V_s
- Secondary current I_s
- Power transferred
- Impedance ratio Z_p/Z_s

## Formula

```
V_s/V_p = N_s/N_p,  I_s/I_p = N_p/N_s,  Z_p/Z_s = (N_p/N_s)²
```

## Explanation

Transformers change AC voltage levels using two coils on a shared core. Power stations step voltage up for efficient transmission; local transformers step it down for homes. In an ideal transformer power in equals power out.

### How to use the Ideal Transformer Calculator

- **Primary turns N_p**
- **Secondary turns N_s**
- **Primary voltage V_p**
- **Primary current I_p**

Results update as you type, every field has its own unit menu, and everything is calculated in your browser.

### How it works

Enter the primary and secondary turns, the primary voltage and the primary current.

### Inputs explained

FieldWhat to enterPrimary turns N_pA numberSecondary turns N_sA numberPrimary voltage V_pUnits: V, kV, mVPrimary current I_pUnits: A, mA, µA, kA

### What each result means

- **Turns ratio N_p/N_s** = [Primary turns N_p]÷[Secondary turns N_s]
- **Secondary voltage V_s** = [Primary voltage V_p]×[Secondary turns N_s]÷[Primary turns N_p]
- **Secondary current I_s** = [Primary current I_p]×[Primary turns N_p]÷[Secondary turns N_s]
- **Power transferred** = [Primary voltage V_p]×[Primary current I_p]
- **Impedance ratio Z_p/Z_s** = ([Primary turns N_p]÷[Secondary turns N_s])^2

### Example values

How the main result changes when **Primary turns N_p** changes and everything else stays at the example values above:

Primary turns N_pSecondary voltage V_s (V)5002375015.33331,00011.51,2509.21,5007.66672,0005.75

## Worked example

Inputs: Primary turns N_p: 1,000; Secondary turns N_s: 50; Primary voltage V_p: 230 V; Primary current I_p: 0.5 A.

Results: Turns ratio N_p/N_s = 20; **Secondary voltage V_s = 11.5 V**; Secondary current I_s = 10 A; Power transferred = 115 VA; Impedance ratio Z_p/Z_s = 400.

## Key terms

- **Turns ratio**: N_p/N_s, which sets the voltage ratio.

## FAQ

**Do transformers work on DC?**
No, they need a changing magnetic flux.

**What is a step-down transformer?**
One with fewer secondary turns, lowering the voltage.

**Why does current go up when voltage goes down?**
Power is conserved: V·I is the same on both sides.

**Are real transformers ideal?**
Large ones are 98–99% efficient.