Optical density measures how strongly a material attenuates light. Each unit of OD reduces the light tenfold: OD 3 safety goggles let through 0.1%. In biology, OD₆₀₀ readings track bacterial growth.
How to use the Optical Density Calculator
- Incident light intensity I₀
- Transmitted light intensity I
Results update as you type, every field has its own unit menu, and everything is calculated in your browser.
How it works
Enter the incident and transmitted intensities in the same units.
Inputs explained
| Field | What to enter |
|---|---|
| Incident light intensity I₀ | A number |
| Transmitted light intensity I | A number |
What each result means
- Optical density (absorbance) = log10([Incident light intensity I₀]÷[Transmitted light intensity I])
- Transmittance = [Transmitted light intensity I]÷[Incident light intensity I₀]×100
Example values
How the main result changes when Incident light intensity I₀ changes and everything else stays at the example values above:
| Incident light intensity I₀ | Optical density (absorbance) |
|---|---|
| 50 | 1.699 |
| 75 | 1.8751 |
| 100 | 2 |
| 125 | 2.0969 |
| 150 | 2.1761 |
| 200 | 2.301 |
Formula
OD = A = log₁₀(I₀/I), T = I/I₀ × 100%
Worked example
Inputs: Incident light intensity I₀: 100; Transmitted light intensity I: 1.
Results: Optical density (absorbance) = 2; Transmittance = 1 %.
Key terms
- Transmittance
- Fraction of light passing through.
Frequently asked questions
What does OD 2 mean?
Only 1% of the light gets through.
Is optical density the same as absorbance?
In spectroscopy, yes; it includes scattering losses too.
What OD do laser goggles need?
Enough to reduce the beam below the safe exposure limit, often OD 4–7.
What is OD₆₀₀?
Absorbance at 600 nm, used to estimate cell density in cultures.