PCB Trace Resistance Calculator

Quick answer

The PCB trace resistance calculator finds the DC resistance of a copper (or other metal) trace from its width, length, thickness and temperature, and from the current or voltage drop it gives the other, the power lost, the cross-section and the sheet resistance.

1 oz/ft² copper ≈ 35 µm.

Temperature coefficient used
0.00393 1/°C
Trace resistance
98.6354
Voltage drop
98.6354
Current
1
Power dissipated
98.6354
Cross-section
0.0089
Sheet resistance
0.5011 mΩ/□
Resistance per length
1.9727

Every trace on a circuit board is a resistor. For signals it hardly matters, but for power rails, LED strings, current-sense paths and battery connections a few tens of milliohms can cost a noticeable voltage drop and heat. Knowing the trace resistance lets you choose the width and copper weight, or decide where a remote-sense line is needed.

Resistance follows the familiar R = ρL ÷ A: it grows with length and falls with cross-sectional area, width × copper thickness. Copper’s resistivity is about 1.72 × 10⁻⁸ Ω·m at 20 °C, and rises by 0.393% per degree, so a trace at 70 °C has about 20% more resistance than at room temperature. Standard 1 oz copper (35 µm) has a sheet resistance of roughly 0.49 mΩ per square: a trace 10 squares long (length 10 times its width) measures about 4.9 mΩ whatever its actual size.

The calculator defaults to copper but also covers aluminium, silver, gold, tin and a custom metal, handy for flex circuits, bus bars or plated finishes. Enter either the current or the measured voltage drop to get the other along with the power dissipated.

How to use the PCB Trace Resistance Calculator

  1. Trace width (W)
  2. Trace length (L)
  3. Trace thickness (T): 1 oz/ft² copper ≈ 35 µm.
  4. Temperature
  5. Conductor material
  6. Resistivity (ρ) at 20 °C
  7. Temperature coefficient (α)
  8. Voltage drop
  9. Current
  10. Voltage drop

Results update as you type, every field has its own unit menu, and everything is calculated in your browser.

How it works

Enter the trace width, length, thickness and temperature and pick the metal. The calculator divides resistivity times length by the cross-section, corrects for temperature with the coefficient α, and applies Ohm’s law for the voltage drop, current and power.

Worked example

A 0.254 mm (10 mil) wide, 50 mm long trace in 1 oz copper (0.035 mm) at 25 °C: R = 1.72 × 10⁻⁸ × 0.05 ÷ (0.254 × 10⁻³ × 0.035 × 10⁻³) × (1 + 0.00393 × 5) = 98.6 mΩ. Carrying 1 A it drops 98.6 mV and dissipates 98.6 mW. Its sheet resistance is 0.501 mΩ per square and its resistance per length 1.97 mΩ/mm.

Resistivity of common conductors (20 °C)

Metal ρ (µΩ·cm) α (1/°C)
Silver 1.59 0.0038
Copper 1.72 0.00393
Gold 2.44 0.0034
Aluminium 2.65 0.00429
Tin 10.9 0.0045

Inputs explained

Field What to enter
Trace width (W) Units: mm, mil, µm, in
Trace length (L) Units: mm, cm, in, m, mil
Trace thickness (T) Units: oz/ft², µm, mil, mm. 1 oz/ft² copper ≈ 35 µm.
Temperature Units: °C, °F, K
Conductor material Choose one: Copper, Aluminium, Silver, Gold …
Resistivity (ρ) at 20 °C Units: µΩ·cm, nΩ·m, Ω·m
Temperature coefficient (α) In 1/°C
Voltage drop Choose one: I know the current, I know the voltage drop
Current Units: A, mA, µA
Voltage drop Units: mV, V

What each result means

  • Trace resistance = [Resistivity used]×([Trace length (L)]÷1000)÷(([Trace width (W)]÷1000)×([Trace thickness (T)]÷1000))×(1 + [Temperature coefficient used]×([Temperature] – 20))
  • Power dissipated = [Voltage drop]×[Current]
  • Cross-section = [Trace width (W)]×[Trace thickness (T)]
  • Sheet resistance = [Trace resistance]×[Trace width (W)]÷[Trace length (L)]×1000
  • Resistance per length = [Trace resistance]÷([Trace length (L)]÷1000)

Formula

R = ρ × L ÷ (W × T) × [1 + α × (T_amb − 20 °C)] · V = I × R · P = V × I · sheet resistance = ρ ÷ T

Worked example

Inputs: Trace width (W): 0.254 mm; Trace length (L): 50 mm; Trace thickness (T): 1 oz/ft²; Temperature: 25 °C; Conductor material: Copper; Voltage drop: I know the current; Current: 1 A.
Results: Temperature coefficient used = 0.00393 1/°C; Trace resistance = 98.6354 mΩ; Voltage drop = 98.6354 mV; Current = 1 A; Power dissipated = 98.6354 mW; Cross-section = 0.0089 mm²; Sheet resistance = 0.5011 mΩ/□; Resistance per length = 1.9727 mΩ/mm.

Key terms

Resistivity (ρ)
Material property: resistance of a unit cube, Ω·m.
Temperature coefficient (α)
Fractional change of resistance per degree.
Sheet resistance
Resistance per square of a thin film, Ω/□.
Copper weight
Copper thickness as oz/ft²; 1 oz ≈ 35 µm.

Frequently asked questions

What is the resistance of a PCB trace?

For 1 oz copper about 0.49 mΩ per square at 20 °C: a 0.25 mm × 50 mm trace (200 squares) is roughly 0.1 Ω.

How does temperature change trace resistance?

Copper gains about 0.39% per °C, roughly +20% between 20 °C and 70 °C.

How do I reduce trace resistance?

Widen the trace, use 2 oz or thicker copper, shorten the path, or add a parallel trace or copper pour on another layer.

What is sheet resistance?

Resistance of a square of conductor of any size: ρ ÷ thickness, in ohms per square.

Is AC resistance the same?

Only at low frequency. Above a few MHz the skin effect pushes current to the surface and raises resistance.

Does plating change the result?

Thin finishes (ENIG, HASL) add little; plated-through vias add their own resistance of about 0.5–1 mΩ each.

Sources

  1. IPC-2221B: Generic Standard on Printed Board Design (table of contents)
  2. Electrical resistivity and conductivity: Wikipedia (table of resistivities)

Cite this calculator

Speedy Calculator. (2026). PCB Trace Resistance Calculator. Speedy Calculator. https://speedycalculator.com/calculators/other/pcb-trace-resistance/