Forward Converter Calculator

Quick answer

The forward converter calculator finds the output voltage and inductor ripple current of a single-switch forward converter from the input voltage, duty cycle, transformer turns and output inductor.

Output voltage V_out
4.8
Inductor ripple current
0.65455

A forward converter is an isolated buck converter: the transformer passes energy straight to the output while the switch is on. It suits medium-power supplies of 100–500 W.

How to use the Forward Converter Calculator

  1. Input voltage V_in
  2. Duty cycle D (%)
  3. Primary turns N_p
  4. Secondary turns N_s
  5. Switching frequency f_s
  6. Output inductance L

Results update as you type, every field has its own unit menu, and everything is calculated in your browser.

How it works

Enter the input voltage, duty cycle (normally below 50%), primary and secondary turns, switching frequency and output inductance.

Inputs explained

Field What to enter
Input voltage V_in Units: V, mV, kV, µV, MV
Duty cycle D (%) A number
Primary turns N_p A number
Secondary turns N_s A number
Switching frequency f_s Units: kHz, MHz, Hz
Output inductance L Units: µH, mH

What each result means

  • Output voltage V_out = [Input voltage V_in]×[Duty cycle D (%)]÷100×[Secondary turns N_s]÷[Primary turns N_p]
  • Inductor ripple current = ([Input voltage V_in]×[Secondary turns N_s]÷[Primary turns N_p] – [Input voltage V_in]×[Duty cycle D (%)]÷100×[Secondary turns N_s]÷[Primary turns N_p])×[Duty cycle D (%)]÷100÷([Switching frequency f_s]×[Output inductance L])

Example values

How the main result changes when Input voltage V_in changes and everything else stays at the example values above:

Input voltage V_in (V) Output voltage V_out (V)
24 2.4
36 3.6
48 4.8
60 6
72 7.2
96 9.6

Formula

V_out = V_in·D·N_s/N_p, ΔI_L = (V_in·N_s/N_p − V_out)·D / (f_s·L)

Worked example

Inputs: Input voltage V_in: 48 V; Duty cycle D (%): 40; Primary turns N_p: 20; Secondary turns N_s: 5; Switching frequency f_s: 200 kHz; Output inductance L: 22 µH.
Results: Output voltage V_out = 4.8 V; Inductor ripple current = 0.65455 A.

Key terms

Core reset
Returning the transformer flux to zero each cycle.

Frequently asked questions

Why is the duty cycle limited to 50%?

The transformer core must reset during the off time.

How is it different from a flyback?

Energy passes directly rather than being stored in the transformer.

What resets the core?

A reset winding, clamp or resonant circuit.

Where are forward converters used?

Industrial and telecom supplies of medium power.