Compressed air is specified in SCFM so that flows measured at different pressures and temperatures can be compared. One cubic foot of air at 100 psig contains about eight standard cubic feet.
How to use the SCFM Calculator
- Actual flow (ACFM)
- Gauge pressure
- Actual temperature
- Standard conditions
- Atmospheric pressure
Results update as you type, every field has its own unit menu, and everything is calculated in your browser.
How it works
Enter the actual flow, gauge pressure and temperature, and choose the standard conditions.
Inputs explained
| Field | What to enter |
|---|---|
| Actual flow (ACFM) | Units: ACFM, m³/min |
| Gauge pressure | Units: psig, barg, kPa (g) |
| Actual temperature | Units: °F, °C |
| Standard conditions | Choose one: 68 °F, 14.696 psia (ASME/ISO), 60 °F, 14.696 psia (US gas industry), 32 °F, 14.696 psia (normal, NCFM) |
| Atmospheric pressure | Units: psia, kPa, bar |
What each result means
- Standard flow = [Actual flow (ACFM)]×(([Gauge pressure] + [Atmospheric pressure])÷14.696)×([Ts]÷([Actual temperature] + 459.67))
- In Nm³/min (approx.) = [Standard flow]×0.0283168×(491.67÷[Ts])
Example values
How the main result changes when Actual flow changes and everything else stays at the example values above:
| Actual flow (ACFM) (ACFM) | Standard flow (SCFM) |
|---|---|
| 50 | 381.5516 |
| 75 | 572.3274 |
| 100 | 763.1032 |
| 125 | 953.879 |
| 150 | 1,144.6548 |
| 200 | 1,526.2063 |
Formula
SCFM = ACFM·(P_act/P_std)·(T_std/T_act) (absolute pressures and temperatures)
Worked example
Inputs: Actual flow (ACFM): 100 ACFM; Gauge pressure: 100 psig; Actual temperature: 80 °F; Standard conditions: 68 °F, 14.696 psia (ASME/ISO); Atmospheric pressure: 14.696 psia.
Results: Standard flow = 763.1032 SCFM; In Nm³/min (approx.) = 20.1344 m³/min.
Key terms
- Standard conditions
- Reference temperature and pressure for gas volumes.
Frequently asked questions
What is the difference between SCFM and ACFM?
SCFM is referenced to standard conditions; ACFM is at actual conditions.
Why does pressure increase SCFM?
Compressed air contains more mass per actual cubic foot.
Which standard should I use?
Check your equipment, since compressor makers often use 68 °F.
What about humidity?
Some standards include 36% RH; this calculator treats dry air.