Insulation is rated by its R-value: the higher the number, the slower heat passes through. R-values of layers in series simply add up. Energy codes specify minimum R-values by climate zone, for example R-38 to R-60 in attics and R-13 to R-21 in walls in much of the U.S.
How to use the Insulation Calculator
- Area
- Layer 1 material
- Layer 1 thickness
- Layer 2 material
- Layer 2 thickness
- Temperature difference
- Every result field is editable: type into Total R-value and Layer 1 thickness plus every other field update to match.
Results update as you type, and every field accepts the units shown in its menu.
How it works
Choose the material and thickness for each layer (set layer 2 to zero thickness if there is none), enter the area and temperature difference. Type a target R-value into the result to find the thickness of layer 1 you need.
R-value per inch
| Material | R per inch | RSI per 25 mm |
|---|---|---|
| Fiberglass batt | 3.2 | 0.56 |
| Blown fiberglass (loose fill) | 2.5 | 0.44 |
| Blown cellulose | 3.5 | 0.62 |
| Mineral wool batt | 3.3 | 0.58 |
| Expanded polystyrene (EPS) | 4 | 0.70 |
| Extruded polystyrene (XPS) | 5 | 0.88 |
| Polyisocyanurate board | 6 | 1.06 |
| Open-cell spray foam | 3.6 | 0.63 |
| Closed-cell spray foam | 6.5 | 1.14 |
| Cotton (denim) batt | 3.5 | 0.62 |
| Straw bale | 1.5 | 0.26 |
| Softwood lumber | 1.25 | 0.22 |
| Concrete | 0.08 | 0.01 |
Inputs explained
| Field | What to enter |
|---|---|
| Area | Units: ft², m², yd², acre |
| Layer 1 material | Choose one: Fiberglass batt, Blown fiberglass (loose fill), Blown cellulose, Mineral wool batt … |
| Layer 1 thickness | Units: in, cm, mm, ft, m |
| Layer 2 material | Choose one: Fiberglass batt, Blown fiberglass (loose fill), Blown cellulose, Mineral wool batt … |
| Layer 2 thickness | Units: in, cm, mm, ft, m |
| Temperature difference | Units: °F, °C / K |
What each result means
- Total R-value = [Layer 1 material]×[Layer 1 thickness]÷0.0254 + [Layer 2 material]×[Layer 2 thickness]÷0.0254
- U-value = 1÷[Total R-value]
- Heat flow through area = [Area]÷0.09290304×[Temperature difference]÷[Total R-value]
Formula
R = Σ R per inch × thickness (in)
RSI = R ÷ 5.678; U = 1 ÷ R
Heat flow (BTU/h) = area (ft²) × ΔT (°F) ÷ R
Worked example
Inputs: Area: 1,000 ft²; Layer 1 material: Fiberglass batt; Layer 1 thickness: 3.5 in; Layer 2 material: Extruded polystyrene (XPS); Layer 2 thickness: 1 in; Temperature difference: 40 °F.
Results: Total R-value = 16.2 R (ft²·°F·h/BTU); U-value = 0.0617 BTU/h·ft²·°F; Heat flow through area = 2,469 BTU/h.
Key terms
- R-value
- Thermal resistance, ft²·°F·h/BTU in the U.S.
- RSI
- Thermal resistance in m²·K/W (R ÷ 5.678).
Frequently asked questions
How do I add R-values?
Layers in series add: R-13 batts plus R-5 foam board make R-18 (ignoring framing).
What R-value do I need?
It depends on climate zone and assembly; attics typically need R-38 to R-60, walls R-13 to R-21, floors R-19 to R-30 (U.S. IECC).
Does compressing insulation reduce its R-value?
Yes. A batt squeezed into a thinner cavity loses R-value, though its R per inch rises slightly.