Single-phase motors need a capacitor to create the phase shift that starts them turning. Three-phase motors can also run from a single-phase supply with a capacitor on the third terminal, at reduced power.
How to use the Motor Capacitor Size Calculator
- Method
- Start-up energy
- Motor rated power
- Supply voltage
- Frequency
Results update as you type, every field has its own unit menu, and everything is calculated in your browser.
How it works
Choose the method and enter the values.
Inputs explained
| Field | What to enter |
|---|---|
| Method | Choose one: From start-up energy, Three-phase motor on single-phase (Steinmetz) |
| Start-up energy | Units: J, kJ |
| Motor rated power | Units: kW, hp, W |
| Supply voltage | Units: V, mV, kV, µV, MV |
| Frequency | Choose one: 50 Hz, 60 Hz |
Example values
How the main result changes when Start-up energy changes and everything else stays at the example values above:
| Start-up energy (J) | Capacitor size (µF) |
|---|---|
| 25 | 945.1796 |
| 37.5 | 1,417.7694 |
| 50 | 1,890.3592 |
| 62.5 | 2,362.949 |
| 75 | 2,835.5388 |
| 100 | 3,780.7183 |
Formula
From start-up energy: C = 2E/V² · Steinmetz: C ≈ 70 µF per kW at 230 V, 50 Hz, scaled by (230/V)²·(50/f)
Worked example
Inputs: Method: From start-up energy; Start-up energy: 50 J; Supply voltage: 230 V.
Results: Capacitor size = 1,890.3592 µF.
Key terms
- Steinmetz connection
- Running a three-phase motor on one phase with a capacitor.
Frequently asked questions
What is the difference between start and run capacitors?
Start capacitors are large and used briefly; run capacitors are smaller and stay connected.
How much power does a Steinmetz connection give?
Roughly 60–80% of the motor's rating.
What voltage rating should the capacitor have?
Typically 370–450 V AC for 230 V motors.
Is this a substitute for the nameplate value?
No, always use the manufacturer's value if available.