RAID (redundant array of independent disks) combines several drives into one volume to gain speed, capacity, protection against drive failure, or a mix of the three. The trade-off is always the same: the more redundancy, the less of your raw capacity you can use.
RAID 0 stripes data across all drives for maximum speed and capacity but survives no failure. RAID 1 mirrors identical copies, so usable space equals one drive. RAID 5 spreads one drive’s worth of parity across the array and survives one failure; RAID 6 uses two parity blocks and survives any two, which is important with today’s large drives, where rebuilding takes many hours and a second failure during the rebuild is a real risk. RAID 10 stripes across mirrored pairs for fast writes and quick rebuilds at 50% efficiency. Nested levels RAID 50 and 60 stripe several RAID 5 or 6 groups, and RAID 5E/5EE build a hot spare into the array so a rebuild can start immediately.
The speed gains shown are theoretical maxima for large sequential transfers, relative to one drive; real performance depends on the controller, workload and cache. And remember: RAID protects against hardware failure, not against deletion, ransomware or fire. It is not a backup.
How to use the RAID Calculator
- RAID level
- Number of drives
- Capacity of one drive
- Number of RAID groups (spans) for RAID 50 / 60
- Cost of one drive
Results update as you type, every field has its own unit menu, and everything is calculated in your browser.
How it works
Choose the RAID level, enter the number of drives, the capacity of one drive and its price (and the number of groups for RAID 50/60). The calculator counts how many drives’ worth of space hold data, multiplies by the drive size and derives efficiency, fault tolerance, speed gains and cost.
Worked example
Four 8 TB drives in RAID 5 give (4 − 1) × 8 = 24 TB usable, 8 TB of parity and 75% efficiency; the array survives one failure and reads up to 3× faster than one drive. At $150 per drive the array costs $600, or $25 per usable TB. Five 1 TB drives in RAID 6 give 3 TB (60%), and six 1 TB drives in RAID 10 give 3 TB (50%) with up to 6× read and 3× write gain.
RAID levels at a glance
| Level | Min. drives | Usable capacity | Failures tolerated |
|---|---|---|---|
| RAID 0 | 2 | n | 0 |
| RAID 1 | 2 | 1 drive | n − 1 |
| RAID 5 | 3 | n − 1 | 1 |
| RAID 6 | 4 | n − 2 | 2 |
| RAID 10 | 4 | n ÷ 2 | 1 (up to n ÷ 2) |
| RAID 50 | 6 | n − groups | 1 per group |
| RAID 60 | 8 | n − 2 × groups | 2 per group |
Inputs explained
| Field | What to enter |
|---|---|
| RAID level | Choose one: RAID 0: striping, RAID 1: mirroring, RAID 1E: striped mirroring, RAID 10 (1+0): mirrored stripes … |
| Number of drives | A number |
| Capacity of one drive | Units: TB, GB, TiB, PB |
| Number of RAID groups (spans) for RAID 50 / 60 | A number |
| Cost of one drive | Amount in your currency |
What each result means
- Usable capacity = max(0, [Data drives])×[Capacity of one drive]
- Capacity used for redundancy (unavailable) = [Number of drives]×[Capacity of one drive] – [Usable capacity]
- Storage efficiency = [Usable capacity]÷([Number of drives]×[Capacity of one drive])×100
- Total drive cost = [Number of drives]×[Cost of one drive]
Formula
Usable = data drives × drive size · RAID 0: n · RAID 1: 1 · RAID 1E: n/2 · RAID 10: ⌊n/2⌋ · RAID 5: n − 1 · RAID 5E/5EE: n − 2 · RAID 50: n − groups · RAID 6: n − 2 · RAID 60: n − 2 × groups · efficiency = usable ÷ raw
Worked example
Inputs: RAID level: RAID 5 – single distributed parity; Number of drives: 4; Capacity of one drive: 8 TB; Cost of one drive: $150.
Results: Usable capacity = 24 TB; Capacity used for redundancy (unavailable) = 8 TB; Storage efficiency = 75 %; Drive failures tolerated (guaranteed) = 1; Drive failures survivable in the best case = 1; Read speed gain (max, vs one drive) = 3 ×; Write speed gain (max, vs one drive) = 1 ×; Minimum number of drives = 3; Configuration check = Valid configuration; Total drive cost = $600.00; Cost per usable TB = $25.00.
Key terms
- Striping
- Splitting data into blocks spread across drives for speed.
- Mirroring
- Keeping identical copies on two or more drives.
- Parity
- Calculated data that allows lost blocks to be reconstructed.
- Hot spare
- A standby drive used automatically to rebuild after a failure.
Frequently asked questions
Which RAID level should I use?
RAID 1 or 10 for simplicity and fast rebuilds, RAID 6 for large arrays of big drives, RAID 5 only with few, smaller drives and good backups, RAID 0 only for scratch data.
Is RAID a backup?
No, it protects against drive failure, not against deletion, corruption, ransomware, theft or fire. Keep separate backups.
Why does my operating system show less space?
Drives are sold in decimal TB (10¹²) while many systems display binary TiB (2⁴⁰): an 8 TB drive shows as about 7.28 TiB.
Can I mix drive sizes?
Most RAID levels treat every drive as the size of the smallest one, so extra space is wasted.
Why is RAID 5 risky with large drives?
Rebuilding a multi-terabyte drive takes many hours, during which a second failure or an unreadable sector loses the array.
How many drives can RAID 10 lose?
At least one; up to half of them if each failure hits a different mirror pair.
Do RAID 5 and 6 speed up writes?
Rarely for small writes, because each update must also rewrite parity; large sequential writes can be faster.