Ideal Transformer Calculator

Quick answer

The ideal transformer calculator finds the secondary voltage and current of a transformer from the primary voltage, current and the number of turns, plus the turns ratio and impedance ratio.

Turns ratio N_p/N_s
20
Secondary voltage V_s
11.5
Secondary current I_s
10
Power transferred
115 VA
Impedance ratio Z_p/Z_s
400

Transformers change AC voltage levels using two coils on a shared core. Power stations step voltage up for efficient transmission; local transformers step it down for homes. In an ideal transformer power in equals power out.

How to use the Ideal Transformer Calculator

  1. Primary turns N_p
  2. Secondary turns N_s
  3. Primary voltage V_p
  4. Primary current I_p

Results update as you type, every field has its own unit menu, and everything is calculated in your browser.

How it works

Enter the primary and secondary turns, the primary voltage and the primary current.

Inputs explained

Field What to enter
Primary turns N_p A number
Secondary turns N_s A number
Primary voltage V_p Units: V, kV, mV
Primary current I_p Units: A, mA, µA, kA

What each result means

  • Turns ratio N_p/N_s = [Primary turns N_p]÷[Secondary turns N_s]
  • Secondary voltage V_s = [Primary voltage V_p]×[Secondary turns N_s]÷[Primary turns N_p]
  • Secondary current I_s = [Primary current I_p]×[Primary turns N_p]÷[Secondary turns N_s]
  • Power transferred = [Primary voltage V_p]×[Primary current I_p]
  • Impedance ratio Z_p/Z_s = ([Primary turns N_p]÷[Secondary turns N_s])^2

Example values

How the main result changes when Primary turns N_p changes and everything else stays at the example values above:

Primary turns N_p Secondary voltage V_s (V)
500 23
750 15.3333
1,000 11.5
1,250 9.2
1,500 7.6667
2,000 5.75

Formula

V_s/V_p = N_s/N_p, I_s/I_p = N_p/N_s, Z_p/Z_s = (N_p/N_s)²

Worked example

Inputs: Primary turns N_p: 1,000; Secondary turns N_s: 50; Primary voltage V_p: 230 V; Primary current I_p: 0.5 A.
Results: Turns ratio N_p/N_s = 20; Secondary voltage V_s = 11.5 V; Secondary current I_s = 10 A; Power transferred = 115 VA; Impedance ratio Z_p/Z_s = 400.

Key terms

Turns ratio
N_p/N_s, which sets the voltage ratio.

Frequently asked questions

Do transformers work on DC?

No, they need a changing magnetic flux.

What is a step-down transformer?

One with fewer secondary turns, lowering the voltage.

Why does current go up when voltage goes down?

Power is conserved: V·I is the same on both sides.

Are real transformers ideal?

Large ones are 98–99% efficient.

Sources

  1. OpenStax: University Physics Volume 2
  2. HyperPhysics (Georgia State University)

Cite this calculator

Speedy Calculator. (2026). Ideal Transformer Calculator. Speedy Calculator. https://speedycalculator.com/calculators/physics/ideal-transformer/